Columbus, Georgia
Georgia's First Consolidated Government
Post Office Box 1340
Columbus, Georgia, 31902-1340
(706) 653-4013
fax (706) 653-4016
Website: www.columbusga.gov/planning
Staff Report
REZN-6-14-1332
- Applicant
- Tiger Creek Development / David B. Erickson
- Owner
- David B. Erickson / Charlie Webster
- Location
- 8800 & 8818 Veterans Parkway
- Acreage
- 50 acres
- Current Zoning Classification
- RE1 (Residential Estate 1) / PUD (Planned Unit Development)
- Proposed Zoning Classification
- PUD (Planned Unit Development)
- Council District
- 6 (Allen)
- PLANNING ADVISORY COMMISSION RECOMMENDATION
- Conditional Approval based on the fact that the request is compatible with
existing land uses and consistent with the Future Land Use map of the 2028
Comprehensive Plan. The recommended conditions are:
1) Roadway access to the property from Veterans Parkway (US 27) shall be as
shown on a plat dated May 27, 2014 by EMC Engineering Services, Inc. named
Conceptual Master Plan or as otherwise specified by the Columbus Traffic
Engineering Division.
2) An Intersection Sight Distance (ISD) Easement shall be conveyed to the
developer as specified by the Traffic Engineering Division on the west side of
Veterans Parkway (US 27) as shown on a plat dated December 20, 2013 by EMC
Engineering Services, Inc. and named Intersection Sight Distance plan. Said
easement shall be approved by the Traffic Engineering Division and recorded in
the Office of the Clerk of Superior Court prior to issuance of any permits for
the property subject to rezoning.
3) Allow an intersection to be constructed along Veterans Parkway at an
interval of less than 800 feet to an interval of 468.92 feet as shown on a plat
dated December 20, 2013 by EMC Engineering Services, Inc. and named D.O.T.
Access Plan.
4) The ISD easement shall be maintained by the developer for a period of three
years, to prevent any vegetation or other obstructions from interfering with
Intersection Sight Distance to the entrance/exit of the proposed subdivision.
Upon the conclusion of this three year timeframe, the owner of the property
where the easement lies is responsible for maintenance of said easement.
5) Maximum lot coverage shall not exceed 55 percent.
6) No access shall be permitted through Oriana Drive during construction.
7) The development shall adhere to the characteristics of the attached PUD site
plan.
8) The developer shall be subject to the major amendments attached to this
ordinance.
9) Buffering on the south and west property lines adjacent to existing
residential uses shall include the following:
(a) Trees planted shall be large maturing species with a minimum trunk
caliper of three inches at planting.
(b) Trees shall be planted at thirty feet intervals and arranged to
complement the existing adjoining landscaped buffer.
(c) Red maple species and cultivars shall not be selected due to poor
overall performance in the area.
(d) At least 50 percent of required trees shall be large maturing
evergreen varieties three inches at planting.
(e) The complete landscaped buffer shall be installed prior to acceptance
of any development section by the Planning Department.
(f) The buffer requirements contained herein shall be permanent as to
developer or any successor in interest.
10) The TDU (Tree Density Unit) requirement for the property subject to
rezoning shall be five (5) TDU's.
11) A two-sided, wood shadow box privacy fence shall be built along the
property lines of 8826, 8850, and 8866 Veterans Parkway, from Parcel 81 to the
Georgia Power easement (as shown on the attached site plan dated 6/25/14).
12) 8866 Veterans Parkway shall have direct access to the public street as
shown on the attached site plan dated 6/25/14.
13) 8826 Veterans Parkway shall have direct access via a twenty feet (20?)
access easement to the public street as shown on the attached site plan dated
6/25/14.
- PLANNING DEPARTMENT RECOMMENDATION
- Conditional Approval based on the fact that the request is compatible with
existing and future land uses. The recommended conditions are the same as those
recommended by the Planning Advisory Commission plus one additional condition:
14) A one hundred feet (100?) buffer along the east property line (as shown on
attached site plan dated 11/26/13) shall be established as an individual lot
not subject to development.
- Fort Benning's Recommendation
- N/A
- DRI Recommendation
- N/A
- General Land use
- Consistent
Planning Area A
Land Use Designation:
Single Family Residential
- Environmental Impacts
- The properties lie within the floodway and floodplain area. The developer will
need an approved drainage plan prior to issuance of a Site Development permit,
if a permit is required.
- City Services
- The properties are served by all city services.
- Traffic Impact
- This rezoning request does not anticipate generating a negative impact on the
transportation network.
Note: Veteran?s Pkwy from Turnberry Lane to SR 315 in Harris County is a
T-SPLOST Project and is scheduled for widening in Band 3 ? (Years 2020-2022).
- Surrounding Zoning
- North ? RE1 (Residential Estate 1)
South ? PUD (Planned Unit Development)/SFR1 (Single Family Residential 1)/SFR3
(Single Family Residential 3)
East ? RE1 (Residential Estate 1)
West ? PUD (Planned Unit Development)/ RE1 (Residential Estate 1)
- Reasonableness of Request
- This request is compatible with existing land-uses.
- School Impact
- School
14-15 Projections
Capacity
Available Space
Anticipated Impact on School
North Columbus Elementary School (PK ? 5)
662
675
13
16
Veterans Memorial Middle School (6 ? 8)
582
650
68
8
Northside High School (9 ? 12)
1294
1525
231
8
Projection
135 Single Family Units: 135 x 24% = 32 students (32.4)
- Buffer Requirements
- The proposed development shall meet the buffer requirements for Master Planned
Developments as defined in the UDO.
- Attitude of Property Owners
- Sixty Four (64) property owners within 300 feet of the subject properties were
notified of the rezoning request. The Planning Department received one call in
regards to the case. She was concerned about the impact on her property.
- Additional Information
- This request is an addition to the previously approved rezoning case
REZN-8-13-2723 under Ordinance #14-7 (attached).
The original request was to build 90 lots that include various houses ranging
from 1,800-2,500 sq. ft. The applicant is planning to add 45 additional homes
to this subdivision for a total of 135 single family dwellings.
Both properties are being rezoned because the overall plan changes the dynamics
of the original site plan. When a PUD zoning is adopted, the site plan is also
adopted. A major change to the site plan requires a rezoning process.
- Attachments
-