- Applicant
- Wade Jordan
- Owner
- Wade Jordan
- Location
- 5064 Warm Springs Road
- Acreage
- 0.6 acres
- Current Zoning Classification
- SFR 1(Single Family Residential 1)
- Proposed Zoning Classification
- RO (Residential Office)
- Council District
- PLANNING ADVISORY COMMISSION RECOMMENDATION
- Approval based upon the fact that it is consistent with the future land-use map
of the 2028 Comprehensive Plan.
- PLANNING DEPARTMENT RECOMMENDATION
- Conditional Approval based on the fact that it is consistent with the future
land-use map of the 2028 Comprehensive Plan. The recommended conditions are: 1)
access to the subject property shall be limited to Warm Springs Road; 2)
storage of vehicles, equipment, materials, or chemicals shall not be permitted
in the rear yard; and 3) Option 3 of the Category C Buffer requirements shall
not apply to this rezoning request.
- Fort Benning's Recommendation
- N/A
- DRI Recommendation
- N/A
- General Land use
- Property is located in Planning Area B
Land Use Deisgnations: Mixed Use
- Environmental Impacts
- The property does not lie within a floodway and floodplain area. The developer
will need an approved drainage plan prior to issuance of a Site Development
permit, if a permit is required.
- City Services
- Property is served by all city services.
- Traffic Impact
- The proposed project is expected to not have a negative impact on the
transportation network.
- Surrounding Zoning
- North - RO (Residential Office)
South - RO (Residential Office)
East - SFR3 (Single Family Residential 3)
West - RO (Residential Office)
- Reasonableness of Request
- The proposed zoning classification is consistent with the future land-use map
of the Comprehensive Plan.
- School Impact
- No school impact.
- Buffer Requirements
- The proposed development shall have a Category C buffer requirement along all
property lines bordered by SFR3 zoning district. The 3 options under Category
C are:
1) 20 feet with a certain amount of canopy trees, under story trees, and shrubs
/ ornamental grasses per 100 linear feet
2) 10 feet with a certain amount of shrubs / ornamental grasses per 100 linear
feet and a wood fence or masonry wall
3) Option 3 shall not apply to this rezoning request (30 feet undisturbed
natural buffer).
- Attitude of Property Owners
- Forty-two (42) property owners within 300 feet were notified of the rezoning
request. The Planning Department did recieve one inquiry concerning this
rezoning request.
- Additional Information
- Option 3 of the Category C Buffer Requirement is not a feasible option since
the rear yard is predominantly vacant of any natural, significant plant growth.