A meeting of the Planning Advisory Commission was held Wednesday, April 16,

2008 in the Council Chambers on the Plaza Level of the Government Center.



Commissioners Present:

Chairperson Karl Douglass



Commissioners: Lucy Sheftall Scott Boyce

Chris Henson Cathy Hodge

Ronny Smith





Staff Members: Will Johnson - Planning Department Chief

John Cantrell ? Zoning Administrator

Lynda Temples ? Recording Secretary



Commissioners Absent: Vice Chairperson Joe Alexander, Commissioners Gladys

Ford, Micheal Eddings



Others Present: George Mize



CALL TO ORDER: Chairperson Karl Douglass called the meeting to order at 9:05

a.m. He explained the rezoning process to the audience.



APPROVAL OF MINUTES: None.



ZONING CASES:



ZC0803-3: A request to rezone 6.119 acres located at 4206 University Avenue.

The

current zoning is Neighborhood Commercial. The proposed zoning is Residential

Office. The property will be used for apartments. George Mize is the

applicant.



Mr. John Cantrell read the Staff Report for this case. This property is

located in Planning District 7. The Land Use Designation shows Social /

Religious / Public / Educational / Utilities.



Policy Statements: It is consistent with Residential Development Policy

Statement #2, sub statement #1.



It is compatible with existing land uses.



The property does not lie within a floodplain and floodway area. The developer

will need an approved drainage plan prior to issuance of a Site Development

Permit.



The property is served by all city services.



The proposed project is not expected to have a negative impact on the

transportation network.



The site shall meet the codes and regulations of the Columbus Consolidated

Government for commercial usage.



School Impact: None.



Buffer Requirement: The proposed development shall have a Category C buffer

requirement along

all property lines bordered by the SFR2 and RMF2 zoning districts. The three

options under

Category C are:

1. 20 feet with a certain amount of canopy trees, understory trees, and

shrubs / ornamental grasses per 100 linear feet.

2. 10 feet with a certain amount of shrubs / ornamental grasses per 100

linear feet and a wood fence or masonry wall.

3. 30 feet undisturbed natural buffer.



Fort Benning Recommendation: None.



DRI Recommendation: None.



Twenty-nine (29) property owners within 300 feet were notified of this rezoning

request. The Planning Department did not receive any comments regarding this

rezoning request.



Conditions: None.



Additional information: None.



George Mize, applicant, came to the podium. This property will be used to

build apartments for students.



Chairperson Douglass asked for discussion and a motion. Commissioner Henson

made a motion to approve this rezoning case. Commissioner Boyce seconded. It

was approved unanimously.





IV. SPECIAL EXCEPTION:



2. SEU0803-1 Special Exception Use request for the operation of a day care

facility

located at 3993 St Mary?s Road.



St. Mary?s Road United Methodist Church submitted an application for the

Special Exception Use cited above. The property is located in an SFR2 (Single

Family Residential) District. The purpose of the Special Exception Use is to

allow for the operation of a day care facility adjacent to St. Mary?s Road

United Methodist Church:



(1) Access: Is or will the type of street providing access to the use be

adequate to serve the proposed special exception use?



Access to the property is adequate for the proposed use. Two commercial

driveways and parking exists on the property.



(2) Traffic and Pedestrian Safety: Is or will access into and out of the

property be adequate to provide for traffic and pedestrian safety, the

anticipated volume of the traffic flow, and access by emergency vehicles?



There will be no impact to the transportation system nor will there be any

impact to pedestrian safety.



(3) Adequacy of Public Facilities: Are or will public facilities such as

school, water, or sewer utilities and police and fire protection be adequate to

serve the special exception use?



There will be no impact to public facilities.



(4) Protection from Adverse Affects: Are or will refuse, service, parking and

loading areas on the property be located or screened to protect other

properties in the area from such adverse effects as noise, light, glare or odor?



The proposed use will be in a building / grounds that were designed for this

type of use. It will not adversely affect surrounding properties.



(5) Hours of Operation: Will the hours and manner of operation of the special

exception use have no adverse effects on other properties in the area?



This use will be open on weekdays.



(6) Compatibility: Will the height, size, or location of the buildings or other

structures on the property be compatible with the height, size, character, or

location of buildings or other structures on neighboring properties?



The proposed use will be compatible with neighboring properties.



Forty-nine (49) property owners within 300 feet of the parcel were notified by

letter of the proposed Special Exception Use. To date, the Planning Department

has not received any comments inquiring about the Special Exception Use

request.



Mike Powell, applicant, came to the podium. This is an existing building that

is attached to the church that will be used for a Day Care Facility. They will

be tenants of the church.



Chairperson Douglass asked discussion and a motion. Commissioner Boyce made a

motion to approve this Special Exception Use. Commissioner Henson seconded.

It was approved unanimously.





TEXT AMENDMENTS:



3. ZC0803-4: Text Amendment Changes to the UDO



Several changes to Chapter 2 need to be amended in the UDO. The aforementioned

changes are:



X = Portions to be deleted

X = Portions to be added



Update Section 2.1.6. Accessory Structures and Table 2.1.4 regarding Accessory

Uses

Section 2.1.6. Accessory Structures.

Accessory structures in all zoning districts shall comply with the requirements

of this Section.

Table 2.1.4.



Minimum Property Standards for Residential

Estate Accessory Structures

TABLE INSET:



Dimension Zoning District

RE10 RE5 RE1

Maximum Height (feet) Same as principal structure

Minimum Lot Coverage Included in coverage for principal structure

Minimum Setbacks (feet)

Front 100 100 N/A (formerly 50?)

Side 50 50 25

Side Corner 50 50 25

Rear 100 75 25 (formerly 50?)

Minimum Building Separation 6 feet from any other structure



2. Location. Accessory structures shall be located in the rear yard for all

residential zoning districts, excluding RE10 and RE5 zoning districts (formerly

residential estate zoning districts).





Amend Section 2.3.5 Residential-Office Zoning District by deleting Subsection D



Current subsection to be deleted:



D. Residential Developments. A residential development within the RO zoning

district shall comply with the standards of the RMF2 zoning district.



New subsection to be added:



Reserved.





Amend Section 2.3.6 Commercial-Office Zoning District ? (CO) by amending Table

2.3.6 (typos) and Subsection F

Table 2.3.6.



Property Development Regulations: Commercial Office Zoning District

TABLE INSET:



Zoning District Property Development Regulations

Min. Lot Size (Square Feet) Max. Density (Units per Acre) Max. Lot Coverage

Min. Lot Width (Feet) Max. Bldg Height (Feet) Minimum Required Yard/Setback

(Feet) Notes

Front Side Side

Corner Rear

CO 3 Acres

(21,780)None (21)50% 110

(250) 125 0 0/15 1 0 0/15 1

Notes. 1. 15 feet when abutting a residential zoning district.





Current subsection to be amended:



F. Minimum Lot Size. Within any property that complies with the three acre

minimum parcel size, minimum lot size shall be 21,780 square feet.



Revised subsection:



F. Minimum Property Size for Rezoning. Property minimum area for a site to be

rezoned to a CO zoning district is three acres.





Amend Section 2.5.15. Planned Industrial/Manufacturing Development ? (PID) by

amending Subsection E



Current subsection to be amended:

E. Maximum Density. Residential density within a PID zoning district shall

comply with the standards of Section 2.5.15, as provided for planned commercial

developments.



Revised subsection:



E. Maximum Density. Residential density within a PID zoning district shall

comply with the standards of Section 2.5.14, as provided for planned commercial

developments.



Tables



Update Table 2.3.1 regarding two typos, one each in NC and GC



Section 2.3.1 Property Development Regulations



Table 2.3.1.



Consolidated Property Development Regulations: Commercial Zoning Districts

TABLE INSET:





Zoning District Property Development Regulations

Min. Lot Size (Square Feet) Max. Density (Units per Acre) Max. Lot Coverage

Min. Lot Width (Feet) Max. Bldg Height (Feet) Minimum Required Yard/Setback

(Feet) Notes

Front Side Side

Corner Rear

UPT

Multifamily and Condo 4,000 None 100% 40 150 25 12 25 40

Nonresidential Uses 4,000 None 100% 40 150 25 0/15 3 0 0

Mixed Uses 4,000 None 100% 40 150 0 0/15 3 0 0 2

CRD See Requirements For UPT Zoning District

NC 4,000

(1,000) None (42) 100% 40 50 20 0/15 3 20 0/15 3 2

RO

Townhouse 1,800

(1,800) 18 50% 20 35 20 8 20 30

Multifamily and Condo 10,000

(1,000) 43 100% 75 150 25 12 25 40

Nonresidential Uses 10,000 43 100% 75 150 25 12 25 40

Mixed Uses 10,000

(1,000) 43 100% 75 150 25 12 25 40 2

CO 130,680

(2,000) 21 50% 250 125 0 0/15 3 0 0/15

3 2,4

GC 4,000 None 100% 40 70 20 (25) 0/15 3 20 0/15 3

SAC 130,680 None 80% 300 120 40 20 20 20

Notes. 1. Number of square feet in parenthesis is the minimum lot area per

individual dwelling unit. 2. Residential uses are to be located above the

ground floor. 3. 15 feet when abutting a residential zoning district. 4. See

Section 2.3.6 for minimum lot size within property zoned CO.





Update Table 2.2.12 by eliminating a typo under ?Side Corner?

Table 2.2.12.



Property Development Regulations: Residential Multifamily 2 Zoning District

TABLE INSET:



Zoning District Property Development Regulations

Min. Lot Size (Square Feet) Max. Density (Units per Acre) Max. Lot Coverage

Min. Lot Width (Feet) Max. Bldg Height (Feet) Minimum Required Yard/Setback

(Feet) Notes

Front Side Side

Corner Rear

RMF2

Townhouse 1,800

(1,800) 18 50% 20 35 20 8 20 230

Duplex 7,500

(2,000) 16.5 40% 60 75 20 10 20 2 30

Multifamily and Condo 7,500

(2,000) 16.5 40% 60 75 20 10 20 2 30

Nonresidential Use 7,500

(2,000) 16.5 40% 60 75 20 10 20 2

sup;30

Note. 1. Number of square feet in parenthesis is the minimum lot area per

individual dwelling unit or nonresidential use.

2. Applies to end units only.





Update Table 2.3.4 regarding typo related to ?Maximum Density?

Table 2.3.4.



Property Development Regulations: Neighborhood Commercial Zoning District

TABLE INSET:



Zoning District Property Development Regulations

Min. Lot Size (Square Feet) Max. Density (Units per Acre) Max. Lot Coverage

Min. Lot Width (Feet) Max. Bldg Height (Feet) Minimum Required Yard/Setback

(Feet) Notes

Front Side Side

Corner Rear

NC 4,000 (1,000) None (42) 100% 40 50 20 0/15 2 20 0/15 2 2

Notes. 1. Reserved. (Number of square feet in parenthesis is the minimum lot

area per individual dwelling unit.) 2. 15 feet when abutting a residential

zoning district.





Update Table 2.3.8 regarding typo related to ?Maximum Density?



Table 2.3.8.



Property Development Regulations for the SAC Zoning District

TABLE INSET:



Zoning District Property Development Regulations

Min. Lot Size (Square Feet) Max. Density (Units per Acre) Max. Lot Coverage

Min. Lot Width (Feet) Max. Bldg Height (Feet) Minimum Required Yard/Setback

(Feet) Notes

Front Side Side

Corner Rear

SAC 130,680 None

(40,000) 80% 100 120 40 20 40 20





Update Table 2.4.1 regarding typo related to ?Maximum Density?

Table 2.4.1.



Consolidated Property Development Regulations: Industrial Zoning Districts

TABLE INSET:



Zoning District Property Development Regulations

Min. Lot Size (Square Feet) Max. Density (Units per Acre) Max. Lot Coverage

Min. Lot Width (Feet) Max. Bldg Height (Feet) Minimum Required Yard/Setback

(Feet) Notes

Front Side Side

Corner Rear

TECH 43,560 1 None

(25) 50% 500 50 100 75 100 100

LMI 7,500 None 100% 40 No Limit 25 8 2 25 15

HMI 15,000 None 100% 80 No Limit 30 20 30 30

Note. 1. Minimum site area for TECH zoning district parcel is 5 acres. 2.

Combined total setback required for both side yards.







Update Table 2.4.1 regarding typo related to ?Maximum Density?

Table 2.4.2.



Property Development Regulations: Technical Zoning District

TABLE INSET:



Zoning District Property Development Regulations

Min. Lot Size (Square Feet) Max. Density (Units per Acre) Max. Lot Coverage

Min. Lot Width (Feet) Max. Bldg Height (Feet) Minimum Required Yard/Setback

(Feet) Notes

Front Side Side

Corner Rear

TECH 43,560 1 None (25) 50% 500 50 100 75 100 100

Note. 1. Minimum site area for TECH zoning district parcel is 5 acres.





Will Johnson, Planning Department Chief, came to the podium to explain the

changes that need to be made to the UDO. Most of the changes are typographical

errors. However some are setback changes.



Commissioner Boyce made a motion to approve these changes. Commissioner Henson

seconded. This Text Amendment was approved unanimously.





NEW BUSINESS: None.



OLD BUSINESS: None.



VII. ADJOURNMENT: 9:35 a.m.





_______________________________

____________________________________

Karl Douglass, Chairperson John Cantrell, Zoning